Re: problems sap webgui when export specials characters as 'ñ' or 'á'
Hello Carmen, Have you tried to use method GUI_DOWNLOAD from class CL_GUI_FRONTEND_SERVICES?You can pass the CODEPAGE on it. Regards,Cris
View ArticleRe: Logoff is not responding in webgui
for correct logout from the system you have to maintain service "logoff" (TC SICF sap/public/icf/logoff) - activate service.next step go to service WEBGUI (sap/bc/gui/sap/its/webgui) open service...
View ArticleITS_UPLOAD error
Hi guys, I need help. I want to upload a file from the ITS using ITS_UPLOAD but I get the interim screen which says that it will be directed automatically but ITS crashes while that happens. I have ITS...
View ArticleRe: ITS_UPLOAD error
Hello Litsa, I really recommend to use a more recent ITS 6.20 patch! Patch level 19 is from August of 2005. The last available patch level (45) is from January of 2013. Please upgrade the ITS 6.20....
View ArticleRe: ITS_UPLOAD error
Hi Litsa, that is an old ITS you are using. What is the backend SAP_BASIS version and support pack level that this STANDALONE ITS 6.20 Patch 19 instance is connecting too?Following note might be of...
View ArticleRe: ITS_UPLOAD error
Unfortunately customer cannot upgrade the ITS at the moment as they will be moving to the integrated ITS soon. Thanx for your reply.Litsa
View ArticleRe: ITS_UPLOAD error
Hi Oisin, thanx for the reply. I have read all the notes and I know that the ITS patch is very old but unfortunately the backend is even worse as we have 4.6D. Its is a standalone Workplacewhich isn't...
View ArticleRe: ITS_UPLOAD error
Hi Litsa, how does the Test Service IT00 behave when you test it?Can you explain the following in more detail:"I tried copying the function but it needs the screen it calls to create the objects."...
View ArticleRe: ITS_UPLOAD error
Hi Litsa, What is the SAP_BASIS version and SP level?Let us have more information and see what can be done. Regards,Cris
View ArticleRe: ITS_UPLOAD error
Hi guys, thanx for your replies. Oisin the IT00 service comes up with a screen with an OK button to begin with and then if I press OK it comes up with a list. Is that what it is supposed to do? Never...
View ArticleSAP ITSMobile trx LM01 : can connect to other server ERP?
Dear SAP ITS specialist,Can you please let me know if I can create a service ITS MOBILE in a server "A" but read/write the information from another server "B". example. In server " A " I have the...
View ArticleRe: ITS_UPLOAD error
re IT00 Internet Service IT00 you should be able to test Upload/Download The following note may be useful in explaining why you are getting the Interim Screens, but not the crash750971 - ITS...
View ArticleSAP ITSMOBILE If possible create an ITSMobile service to another server?
Dear SpecialistI have a question:Is possible create a ITSMobile service for transaction LM01 (trx customized ZLM01) in a server "A" (located in the country XXX) but when save/read/modify do this in...
View ArticleRe: SAP ITSMobile trx LM01 : can connect to other server ERP?
Hello EP, Overall what you want is not possible.If it is just a URL link to server B to show information this should be possible, but it not possible to use the ITSMobile service on A if you wish to...
View ArticleRe: SAP ITSMOBILE If possible create an ITSMobile service to another server?
Dear Edward, Could you please clarify whether you are considering using an RFC to call something in server B? Are both servers part of the same System ID? Or are both from different SIDs? Regards,Cris
View ArticleRe: SAP ITSMobile trx LM01 : can connect to other server ERP?
Hello EP, As Oisín mentioned, the ITSmobile application would need to access the DB from the server it is running. I see only one exception: if you use, in your application logic, an RFC to reach the...
View ArticleMC9090 FKey HTML META Key Mapping
Hello All, I've been trying to map the FKeys from the RF device to SAP in ITS and have had no success. The enter button works and all numerical keys work. I've seen this issue raised in many forums,...
View ArticleRe: MC9090 FKey HTML META Key Mapping
Just as I post this I get the solution. Please implement the following change to DEVINCLUDE_SYMBOL3090 in order to use the 53 key MC9090:(ignoring the starting "<!--" and finishing "-->"<!--...
View ArticleRe: MC9090 FKey HTML META Key Mapping
Hello Lane, thanks for sharing. For others following this thread the following WIKI from Cristiano Hansen might also be of interest How to obtain the function key values for ITSmobile applications...
View ArticleRe: ITS Mobile Login Screen size on Motorola MC9190
Hi Kirill, your answer helped me to make the Logon-Screen usable on our mobile hardware/software (Datalogic Falcon X3+ with Wavelink TelnetCE Industrial Browser). I added a Z-Class and redefined the...
View Article